PRESSURE BOOSTING SYSTEMS
D
SPEEDMATIC MASTER 101110 VSD
Variable speed driver for a single phase pump or three phase pump. 230v IN and either 230v OUT or 230v 3 phase out. These can
be mounted individually or in a group of 2, 3 or 4 pumps communicating and operating in MASTER-SLAVE mode with alternating
sequence of operation. The communication of 2 devices is direct using cables. The communication of 3 or 4 units is carried out
through a centre control communication – ask for details. Easy to set up and operate as it is only necessary to connect and the select
the set point pressure. Built in pressure sensor and current sensor with digital reading. (ART) Automatic Reset Test. If the device has
stopped due to dry run operation, the ART tries to restart the pump periodically to see if the water has returned. Maximum 166 L/M
Features
Variable Speed
Adjustable Pressure
Pressure Range 0.5-12 Bar
Applications
Water Boosting
Single & Twin Boosters
MODEL
VOLT IN
101110
T
230v
VOLT OUT
230v OR 230v 3 Ph
INLET/OUTLET MAX AMP
H x W x L mm
Kg
CODE
X9A / 10A
196 x 178 x 262
2.5
9000-0140
1¼” x 1¼”
D
SPEEDMATIC MASTER 1309 VSD
Variable speed driver for one three phase 400v pump. 400v IN 400v 3 phase out These can be mounted individually or in a group of
2, 3 or 4 pumps communicating and operating in MASTER-SLAVE mode with alternating sequence of operation. The communication
of 2 devices is direct using cables. The communication of 3 or 4 units is carried out through a centre control communicationr – ask
for details. Easy to set up and operate as it is only necessary to connect and the select the set point pressure. Built in pressure sensor
and current sensor with digital reading. (ART) Automatic Reset Test. If the device has stopped due to dry run operation, the ART tries
to restart the pump periodically to see if the water has returned. Maximum 250 L/M
Features
Variable Speed
Adjustable Pressure
Pressure Range 0.5-12 Bar
Applications
Water Boosting
Single & Twin Boosters
T T
X X
MODEL
VOLT IN
VOLT OUT
INLET/OUTLET
MAX AMP
H x W x L mm
Kg
CODE
1309
400v
400v 3 Ph
1¼” x 1¼”
9
240 x 226 x 280
5
9000-0150
173